La Casella power station
Part of the Global Oil and Gas Plant Tracker, a Global Energy Monitor project. |
Related categories: |
La Casella power station is an operating power station of at least 1524-megawatts (MW) in Castel San Giovanni, Piacenza, Italy with multiple units, some of which are not currently operating. It is also known as Edoardo Amaldi.
Location
Table 1: Project-level location details
Plant name | Location | Coordinates (WGS 84) |
---|---|---|
La Casella power station | Castel San Giovanni, Piacenza, Italy | 45.0904, 9.4805 (exact)[1] |
The map below shows the exact location of the power station.
Unit-level coordinates (WGS 84):
- Unit 1, Unit 1-4 Upgrade, Unit 2, Unit 3, Unit 4, Unit LC6-1, Unit LC6-2: 45.0904, 9.4805
Project Details
Table 2: Unit-level details
Unit name | Status | Fuel(s) | Capacity (MW) | Technology | CHP | Start year | Retired year |
---|---|---|---|---|---|---|---|
Unit 1 | operating[2] | fossil gas - natural gas[3] | 381[3] | combined cycle[3] | – | 2002[3] | – |
Unit 1-4 Upgrade | pre-permit[4] | fossil gas - natural gas[5] | 148[4] | combined cycle[5] | – | 2025[4] | – |
Unit 2 | operating[2] | fossil gas - natural gas[3] | 381[3] | combined cycle[3] | – | 2002[3] | – |
Unit 3 | operating[2] | fossil gas - natural gas[3] | 381[3] | combined cycle[3] | – | 2003[3] | – |
Unit 4 | operating[2] | fossil gas - natural gas[3] | 381[3] | combined cycle[3] | – | 2003[3] | – |
Unit LC6-1 | pre-permit[6][4] | fossil gas - natural gas[7] | 590[7] | gas turbine[7] | – | – | – |
Unit LC6-2 | pre-permit[6] | fossil gas - waste heat from natural gas, bioenergy - unknown[7] | 280[7] | steam turbine[7] | – | – | – |
CHP is an abbreviation for Combined Heat and Power. It is a technology that produces electricity and thermal energy at high efficiencies. Coal units track this information in the Captive Use section when known.
Table 3: Unit-level ownership and operator details
Unit name | Owner |
---|---|
Unit 1 | Enel SpA [100.0%] |
Unit 1-4 Upgrade | Enel SpA [100.0%] |
Unit 2 | Enel SpA [100.0%] |
Unit 3 | Enel SpA [100.0%] |
Unit 4 | Enel SpA [100.0%] |
Unit LC6-1 | Enel SpA [100.0%] |
Unit LC6-2 | Enel SpA [100.0%] |
Background
In 2020, Enel produced a draft proposal for an upgrade to La Casella power station units 2 and 3 which would increase their capacities by 37 MW each.[8] Additionally, Enel began the project "Centrale Termoelettrica La Casella – Installazione di una Nuova Unità a gas" that same year. The new gas unit is proposed to be built in two phases, a gas turbine of 590 MW is set to be built and operated in the first phase, then a 280 MW waste steam recovery system is expected making the units into one combined cycle.[9]
Articles and Resources
References
- ↑ https://web.archive.org/web/20230103182122/https://datasets.wri.org/dataset/globalpowerplantdatabase. Archived from the original on 03 January 2023.
{{cite web}}
: Check date values in:|archive-date=
(help); Missing or empty|title=
(help) - ↑ 2.0 2.1 2.2 2.3 https://web.archive.org/web/20221107230119/https://transparency.entsoe.eu/. Archived from the original on 07 November 2022.
{{cite web}}
: Check date values in:|archive-date=
(help); Missing or empty|title=
(help) - ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 3.14 3.15 (PDF) https://energia.regione.emilia-romagna.it/leggi-atti-bandi-1/documenti-e-pubblicazioni/eventi/2010/la-sfida-delle-fonti-tradizionali-petrolio-e-dintorni/Cimaglia_Le_centrali_elettriche_di_Porto_Corsini_e_di_La_Casella_e_la_loro_efficienza.pdf.
{{cite web}}
: Missing or empty|title=
(help) - ↑ 4.0 4.1 4.2 4.3 https://web.archive.org/web/20240422191944/https://va.mite.gov.it/it-IT/Oggetti/Info/7510. Archived from the original on 22 April 2024.
{{cite web}}
: Missing or empty|title=
(help) - ↑ 5.0 5.1 https://web.archive.org/web/20240426194654/http://notedimarcogrondacci.blogspot.com/2021/01/quante-centrali-gas-vogliono-costruire.html. Archived from the original on 26 April 2024.
{{cite web}}
: Missing or empty|title=
(help) - ↑ 6.0 6.1 (PDF) https://web.archive.org/web/20221206032255/https://www.qualenergia.it/wp-content/uploads/2022/05/rapporto-MiTE-autorizzazioni-impianti-storage-maggio-2022.pdf. Archived from the original (PDF) on 06 December 2022.
{{cite web}}
: Check date values in:|archive-date=
(help); Missing or empty|title=
(help) - ↑ 7.0 7.1 7.2 7.3 7.4 7.5 https://va.minambiente.it/File/Documento/449243.
{{cite web}}
: Missing or empty|title=
(help) - ↑ "Centrale "Edoardo Amaldi" di La Casella Progetto di Upgrade impianto". ministero della transizione ecologica. July 17, 2020. Retrieved November 8, 2021.
{{cite web}}
: CS1 maint: url-status (link) - ↑ Enel (October 28, 2020). "Centrale Termoelettrica "Edoardo Amaldi" di La Casella Installazione di una Nuova Unità a gas". ministero della transizione ecologica. Retrieved November 8, 2021.
{{cite web}}
: CS1 maint: url-status (link)
Additional data
To access additional data, including an interactive map of gas-fired power stations, a downloadable dataset, and summary data, please visit the Global Oil and Gas Plant Tracker on the Global Energy Monitor website.